ADJ 5.4
Repairs & Adjustments
Initial Issue
Adjustment
1.
Enter the Diagnostic mode (Accessing UI Diagnostics.).
2.
Select NVM Read/Write.
3.
Adjust the Lead Edge using the NVM locations specified in
Table 2
until the measured
value falls within specifications.
•
each bit equals approximately 0.06 MM.
•
increasing the value moves the image toward the Lead Edge
4.
Repeat Check and Adjustment until the Lead Edge measurement is within the specified
range.
Table 2 NVM List
Chain Link Name
Min.
Initial Max
711-140
DADF Lead Reg. Adjustment (Side 1)
Replace All
80
129
230
711-141
DADF Lead Reg. Adjustment (Side 2)
Replace All
80
129
230