BUS Updated 12/2011
07/2011
6-14
WorkCentre 5335 Family Service Documentation
Component Control
Initial Issue
General Procedures & Information
Component Control
Purpose
The purpose of the Component Control is to display the logic state of input signals and to ener-
gize output components.
NOTE: Refer to
Table 1
for a list of all IOT, IIT, DADF, Tray Module, and HCF Input Compo-
nents listed by Chain/Link number.
Refer to
Table 2
for a list of all IOT, IIT, DADF, Tray Module, and HCF Output Components
listed by Chain/Link number.
Refer to
Table 3
for a list of all Integrated Office Finisher Input Components listed by Chain/
Link number.
Refer to
Table 4
for a list of all Integrated Office Finisher Output Components listed by Chain/
Link number.
Refer to
Table 5
for a list of all Office Finisher LX Input Components listed by Chain/Link num-
ber.
Refer to
Table 6
for a list of all Office Finisher LX Output Components listed by Chain/Link
number.
Procedure
1.
Enter Diagnostic Mode (
Accessing UI Diagnostics
).
2.
Press the Machine Status button on the Control Panel.
3.
Select the Tools tab on the UI screen.
4.
System Settings and Common Service Settings will be highlighted.
5.
In the Features column, select Maintenance / Diagnostics.
Scroll to and select IO Check.
6.
Select Component Control.
7.
Input Chain-Link number, then press Start.
•
In case of INPUT Component:
Indicates current status in Status column.
Count up (+1) when switching. (High to Low, Low to High)
•
In case of OUTPUT Component:
Activates component
8.
Press Stop button after confirming.
Stacking Components
NOTE: Some components cannot be energized at the same time as another component. If you
activate such a combination of components, the first component switched on will be automati-
cally switched off.
1.
When performing multiple component checking, input new Chain-Link number after one
(or several) component(s) is (are) in operation.
NOTE: Only latest Chain-Link number is displayed.
2.
When confirming the status of another component still in operation, select Enter Number
then input Chain-Link number of applicable component.
3.
Select Stop key after confirming. Stop operation of component indicated on screen.
Table 1 Input Component Control List - IOT/IIT/DADF/TM/HCF
Chain-
Link
Component Name
Description
005-102
Document Sensor
H = No paper detected by Document Sensor
005-110
Registration Sensor (DADF)
L = Paper detected by Registration Sensor
005-205
DADF Feed Out Sensor
H = Paper detected on Feed Out Sensor
005-206
DADF Pre-Reg. Sensor
H = Paper detected on Pre Registration Sensor
005-211
DADF Inverter Sensor
H = Paper detected on Inverter Sensor
005-212
DADF Feeder Cover Interlock
Switch
H = Feeder Cover Open
005-213
DADF Interlock Switch
H = Platen Interlock Open
005-215
DADF APS Tray Sensor #1
L = Light not blocked by Actuator
005-216
DADF APS Tray Sensor #2
L = Light not blocked by Actuator
005-217
DADF APS Tray Sensor #3
L = Light blocked by Actuator
005-218
DADF #1 APS Sensor
L = Paper detected on APS No.1 Sensor.
005-219
DADF #2 APS Sensor
L = Paper detected on APS No.1 Sensor.
005-220
DADF #3 APS Sensor
L = Paper detected on APS No.1 Sensor.
005-221
DADF Tray Size Sensor No.1
L = Paper detected on APS No.1 Sensor.
005-222
DADF Tray Size Sensor No.2
L = Paper detected on APS No.1 Sensor.
005-224
Scan Start
H = Scan signal ON
042-200
Drum Motor
Detect the rotation of Drum Motor.
042-201
Main Motor
Detect the rotation of Main Motor.
042-202
Fan Assy-Fuser Fail
Detect the rotation of Fuser Fan.
042-203
Fan Assy-CRU Fail
Detect the rotation of CRU Fan.
062-201
Sheet Abort
Document Registration
L = ON
062-212
IIT Registration Sensor
Deactuation of Registration Sensor
L = ON
062-240
ADF Exist
DADF is installed.
H = ON status
062-251
APS Sensor 1
Document detected.
H = APS ON
062-253
APS Sensor 3
Document detected.
H = APS ON
062-272
Scan Start
L = Scan available
062-300
Platen I/L Switch
L = Platen is closed
062-301
Angle Sensor
L = Platen is closed
071-101
Tray 1 No Paper Sensor
Detects the Tray 1 No Paper Sensor ON/OFF.
071-102
Tray 1 Level Sensor
Detects the Tray 1 Level Sensor ON/OFF.
071-104
Tray 1 Paper Size Switch
Detect Tray 1 Paper Size Sensor Digital On/Off
071-105
Tray 1 Pre Feed Sensor
072-101
Tray 2 No Paper Sensor
Detects the Tray 2 No Paper Sensor ON/OFF.