BUS Updated 12/2011
07/2011
2-826
WorkCentre 5335 Family Service Documentation
091-600, 091-912
Initial Issue
Status Indicator RAPs
091-600 Humidity Sensor Fail RAP
BSD-ON:
BSD 9.4 - Transfer
Environment Humidity Sensor failure.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Humidity Sensor for failure:
Component Control
[092-201] (
PL 8.2
).
•
The connection between the Hum and Temp Sensor
P/J150
and the MCU PWB
P/J415
for open circuit, short circuit, and poor contact
If no problems are found, reload the machine software (
GP 16
).
091-912 Drum Cartridge Life End RAP
BSD-ON:
BSD 9.1 - CRU Life Control
Drum Not In Position.
Procedure
Reinstall or replace the Drum (
PL 8.1
) as necessary.