BUS Updated 12/2011
07/2011
2-785
WorkCentre 5335 Family Service Documentation
062-398, 062-500
Status Indicator RAPs
Initial Issue
062-398 IIT-Cont I/O Cable Connection Fail RAP
BSD-ON:
BSD 3.3 - ESS-IIT Communication
An ESS I/O Cable connection error was detected.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
1.
Turn the power OFF and ON.
2.
Turn the power OFF and check the coaxial cable between the IIT PWB
P/J7191
and the
ESS PWB
P/J336
for open circuit, short circuit, and poor contact.
If no problems are found, replace the following parts in sequence:
•
Reload the machine software (
GP 16
).
•
ESS PWB (
PL 35.2
)
•
IIT PWB (Switch the EEPROM) (
PL 1.6
)
062-500 Write to Error During Download RAP
BSD-ON:
BSD 3.3 - ESS-IIT Communication
Job Fail. An error has occurred during the process of writing data to the IISS-ROM. An error
was detected when writing data to the IISS-ROM. Not able to carry out normal operation
because ROM content is missing.
Procedure
Retry job. If retry failed, replace the IIT PWB (
PL 1.6
) and retry the download operation. If the
problem persists, replace the ESS PWB (
PL 35.2
).