BUS Updated 12/2011
07/2011
3-18
WorkCentre 5335 Family Service Documentation
Initial Issue
Image Quality
IQS3 Exposure Level Specification
Procedure
Use Side A of the Standard Test Pattern.
In the Standard Copy mode, and with the copy darkness control set at the middle of the scale,
the 0.20G(Or0.20B) line pair must be copied completely.
In the Standard Copy mode, and with the copy darkness control set two level lighter from at the
middle of the scale, the 0.10 line pair should not copy at all (
Figure 1
).
Figure 1 Exposure Level