BUS Updated 12/2011
07/2011
6-19
WorkCentre 5335 Family Service Documentation
Component Control
General Procedures & Information
Initial Issue
077-002
Registration Clutch
Turns ON the Registration Clutch.
By combining this with Main Drive Motor[042-041], it is also able to drive the Registration Roll.
-
-
077-004
Exit Gate Solenoid
Switches the Exit Gate.
Strong current for the first 110msec after the attraction had started, then switching to weak current
When Off: Output to #1 Exit. When On: Output #2 Exit
-
077-010
#1 OCT Motor
(CW 2-phase excitation
mode)
Move #1 Exit Roll toward the shaft direction (Turn on for 1000msec and Time-out)
CW: Move Exit Roll to the O/B side of M/C.
Y -1 sec. 077-011. 012, 013
077-011
#1 OCT Motor
(CCW 2-phase excitation
mode)
Move #1 Exit Roll to the shaft direction (Turn on for 1000msec and Time-out)
CCW: Move Exit Roll to the I/B side of M/C.
Y -1 sec. 077-010, 012, 013
077-012
#1 OCT Motor
(CW 1-2-phase excitation
mode)
Move #1 Exit Roll to the shaft direction (Turn on for 1000msec and Time-out)
CW: Move Exit Roll to the O/B side of M/C
Y -1 sec. 077-010, 011, 013
077-013
#1 OCT Motor
(CCW 1-2-phase excita-
tion mode)
Move #1 Exit Roll to the shaft direction. (Turn on for 1000msec and Time-out)
CCW: Move Exit Roll to the I/B side of M/C.
Y -1 sec. 077-010, 011, 012
077-014
Exit 2 Drive Motor
(63 speed forward rota-
tion/MAX)
Drives the Transport Roll of the Exit Unit (Max Speed Normal Rotation)
Exit output direction
-
077-015, 016, 017
077-015
Exit 2 Drive Motor
(126 speed reverse rota-
tion/MAX)
Drives the Transport Roll of the Exit Unit (Max Speed Normal Rotation)
Exit Output direction
-
077-014, 016, 017
077-016
Exit 2 Drive Motor
(63 speed forward rota-
tion/MAX)
Drives the Transport Roll of the Exit Unit (Max Speed Reverse Rotation)
Duplex direction
-
077-014, 015, 017
077-017
Exit 2 Drive Motor
(126 speed reverse rota-
tion/MAX)
Drives the Transport Roll of the Exit Unit (Max Speed Reverse Rotation)
Duplex direction
Y
077-014, 015, 016
077-030
Output of the signal for
TM Feed Ready
Turns on the Feed Ready signal
-
077-031
Output of the signal for
IOT Regi Stop
Turn on the Reg.Stop signal.
-
077-032
Output of the signal for
IOT Feed ON
Turn on the Feed On signal.
-
077-033
TM T/A Motor in full
speed
Drive TM T/A Motor at 155 mm/sec.
-
077-034
TM T/A Motor in half
speed
Drive TM T/A Motor at 145 mm/sec.
-
077-050
Takeaway Motor
Drives Takeaway Motor with 1-2 phase excitation. max. speed. (Output direction)
Drives Takeaway Roll 2, MSI Feed Roll, and MSI Takeaway Roll.
077-051
Takeaway Motor
Drives Takeaway Motor with 2 phase excitation. max. speed. (Output direction)
Drives Takeaway Roll 2, MSI Feed Roll, and MSI Takeaway Roll.
077-070
Duplex Drive Motor
Drives Duplex Drive Motor with 1-2 phase excitation. max. speed. (Pull-in direction)
Table 2 Output Component Control List - IOT/IIT/DADF/HCF
Chain-
Link
Component Description
Time-out conflicts