BUS Updated 12/2011
07/2011
4-84
WorkCentre 5335 Family Service Documentation
REP 10.3, REP 10.4
Initial Issue
Repairs & Adjustments
REP 10.3 Fuser
Parts List on
PL 7.1
Removal
CAUTION
The Fuser is Hot, do not start servicing the Fuser until has cooled down.
1.
Switch off the power and disconnect the power cord.
2.
Open the Left Hand Cover and remove the Fuser (
Figure 1
).
a.
Loosen the knobs (2).
b.
Hold the Fuser by the handles and remove it.
Figure 1 Removal
Replacement
1.
To install, carry out the removal steps in reverse order.
REP 10.4 Fuser Exit Sensor
Parts List on
PL 7.1
Removal
CAUTION
The Fuser is Hot, do not start servicing the Fuser until has cooled down.
1.
Switch off the power and disconnect the power cord.
2.
Open the Left Hand Cover and remove the Fuser (
Figure 1
).
a.
Loosen the knobs (2).
b.
Hold the Fuser by the handles and remove it.
Figure 1 Removal
3.
Remove the Plate (1 Screw) (
Figure 2
).
Figure 2 Removing Screw
a
b
a
b
3