BUS Updated 12/2011
07/2011
2-983
WorkCentre 5335 Family Service Documentation
124-390, 124-391
Status Indicator RAPs
Initial Issue
124-390 CRUM OEM Fail All (2) RAP
System Fail. All three CRUM OEM destinations are not set (0 or different values are set).
#Case-(2). The CRUM OEM destinations stored in three positions match but their values are
not set (0).
Procedure
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
•
Replace the machine, or replace the MCU Board (
PL 18.2
). Reload Firmware (
GP 16
)
124-391 CRUM OEM Fail MCU (2) RAP
System Fail. One of CRUM OEM destinations is different from the others (IOT). #Case-(2).
One of the CRUM OEM destinations stored in three positions does not match (Data stored in
the MCU Board does not match).
Procedure
•
(Software available for
Machine ID/Billing Data
)
•
Enter
Machine ID/Billing Data
. Master SYS1 to resolve the problem. If the problem per-
sists, replace the MCU PWB (
PL 18.2
).
(Software unavailable for
Machine ID/Billing Data
)
Reload Firmware (
GP 16
). Replace the MCU PWB (
PL 18.2
).
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP