BUS Updated 12/2011
07/2011
4-177
WorkCentre 5335 Family Service Documentation
REP 19.1, REP 19.2
Repairs & Adjustments
Initial Issue
REP 19.1 HCF Tray 6
Parts List on
PL 10.1
Removal
1.
Switch off the power and disconnect the power cord.
2.
Open the HCF Tray by pulling the tray toward you.
3.
Remove all paper from the tray.
4.
Using a small screwdriver, or other small, blunt instrument, release the stopper on each
rail of the tray by inserting the screwdriver into the hole of the stopper and pulling the tray
toward you.
5.
Remove the tray by pulling it toward you.
Replacement
1.
Slide the rails (2) into the HCF housing.
2.
Line up the rails of the tray with the adjoining rails of the HCF and push the tray into place.
3.
Place previously removed paper, or fresh paper, into the tray.
REP 19.2 HCF Feeder
Parts List on
PL 10.1
Removal
1.
Switch off the power and disconnect the power cord.
2.
Remove the HCF Tray (
REP 19.1
).
3.
Open the Feeder Top Cover.
4.
Remove the (2) screws used to secure the HCF Feeder on its rail (
Figure 1
).
Figure 1 Feeder Securing Screws
5.
Slide the HCF Feeder toward you.
1
Feeder
Securing