BUS Updated 12/2011
07/2011
3-28
WorkCentre 5335 Family Service Documentation
Initial Issue
Image Quality
IQS13 Background Specification
Procedure
Use Side A of the Standard Test Pattern.
Compare images of the test pattern, (
Figure 1
) made from the document glass, with the visual
scale,82P448.
The background of the images must not be darker than the reference area “C” (
Figure 1
).
Figure 1 Test Pattern