Status Indicator RAPs
Initial Issue
027-752 Required User Entry Not Entered RAP
The instruction to start the job is issued but the required user entry not entered.
Procedure
•
Do not link the entry box to instructions that require user entry.
•
Set preset values for the items in the instruction requiring user entry.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 6
,
GP 16
)
027-753 Job Flow Service Disabled RAP
The system attempted to create a job to recall an external service while the Job Flow Service is
invalid.
Procedure
•
Ask customer to enable the Job Flow Service.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 6
,