WorkCentre 5335 Family Service Documentation
116-389, 116-390
Status Indicator RAPs
Initial Issue
116-389 RAM Install RAP
BSD-ON:
BSD 16.1 - ESS
BSD-ON:
BSD 34.1 - FAX
The control logic detected that the required RAM capacity is not installed or available.
1.
The system detected that additional RAM was not installed, even though the system con-
figuration (with HDD etc.) requires the installation of additional RAM.
2.
Insufficient System Memory was detected when SW optional function was enabled.
[Option name to be detected]
•
Printer Kit
•
Scanner Kit
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Reinstall or replace the DIMM (
PL 35.2
).
•
Remove and re-install or replace the System Memory and Page Memory DIMMs (
PL
35.2
).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)
116-390 ROM NVM Mismatch RAP
BSD-ON:
BSD 16.1 - ESS
BSD-ON:
BSD 34.1 - FAX
Incompatible versions of the standard ROM and NVM are detected.
Procedure
1.
Initialize the NVM by following the instructions on the LCD display.
2.
If the NVM is not to be initialized, use a compatible version of the Controller ROM (Stan-
dard ROM).