BUS Updated 12/2011
07/2011
4-47
WorkCentre 5335 Family Service Documentation
REP 6.7, REP 6.8
Repairs & Adjustments
Initial Issue
Figure 6 IIT PWB
Replacement
1.
To install, carry out the removal steps in reverse order.
2.
Adjust the position of Full Rate/Half Rate Carriages (
ADJ 6.2
)
REP 6.8 Light Guide
Parts List on
PL 1.4
Removal
NOTE: Do not touch the Light Guide using bare hands.
1.
Switch off the power and disconnect the power cord.
2.
Remove the DADF (
REP 5.1
)
3.
Remove the Platen Glass (
REP 6.3
)
4.
Move the Full Rate Carriage to the notch on the Frame.
5.
Remove the LED Bracket (
Figure 1
)
(1) Remove the screws (x3).
(2) Remove the LED Bracket.
Figure 1 LED Bracket Removal
6.
Remove the Light Guide (
Figure 2
)
(1) Remove the screw.
(2) Remove the Spring Guide.
(3) Remove the screw.
(4) Remove the Spring Guide.
(5) Remove the Light Guide.