BUS Updated 12/2011
07/2011
6-4
WorkCentre 5335 Family Service Documentation
Accessing UI Diagnostics, Printing CSE Reports
Initial Issue
General Procedures & Information
•
Faults - this selection opens the following menu:
–
Jam Counter
–
Failure Counter
–
Shutdown History
•
Restore NVM Values
•
MAX Setup
- this selection opens the following menu:
–
Adjust Toner Density (
ADJ 9.4
)
Measure Sensor State
Adjust Toner Density
–
IIT Calibration
- this selection opens the following menu:
White Reference Adjustment
CCD Calibration
Optical Axis Correction (
ADJ 6.1
)
•
The following selections will appear (on 3rd page):
–
USB Key
–
Power On Self Test
Off
On
–
Delete All Certificates / Initialize Settings
Printing CSE Reports
Reports Menu
To access the menu of printable reports:
1.
Enter the Service Rep. Mode (
Entering and Exiting Service Rep. Mode
).
2.
Press the Machine Status button on the Control Panel.
3.
The Machine Information tab will be selected and displayed.
4.
Select Print Reports.
5.
Select CE. The following report selections will be displayed:
•
Debug Log Report
•
HFSI Report
•
Jam Report
•
Shutdown Report
•
Failure Report
•
NVM SETTING VALUE LIST
6.
Select the required report and press Start. The report will be printed.
Debug Report
This report prints out debug messages with the time when the data was stored. The output for-
mat is as follows: MM/DD/YYYY HH:MM:SS (AM/PM), [xxx] Recorded message.
HFSI Report
The HFSI information stored in the IOT will be displayed.
Table 1
shows the format.
NOTE: The Spec Life counter is not always related to the number of fed sheets. Some
counters increment according to document length; some are revolutions of a particular roll, etc.
Refer to
Detailed Maintenance Activities
for details.
Jam Report
The Jam Report displays a pre-programmed list of jam faults, and the number of occurrences
since that last time the counter was cleared.
Table 1 HFSI Report
Chain-
Link
Current
Value
Spec Life
Average
per Month
Last
Replaceme
nt (P1)
Second Last
Replacement
(P2)
Third Last
Replacement
(P3)
xxx-xxx
6-digit Dis-
play
current
count in
location
count when
replace-
ment due
(see Note)
average
monthly (30
days)
usage
X/Y Count at
most recent
replacement.
Reason
code:
U=UM,
S= SM
O= Other
X/Y Count at
2 replace-
ments ago.
Reason code:
U=UM,
S= SM
O= Other
X/Y Count at
3 replace-
ments ago.
Reason code:
U=UM,
S= SM
O= Other