BUS Updated 12/2011
07/2011
2-486
WorkCentre 5335 Family Service Documentation
027-725, 027-726
Initial Issue
Status Indicator RAPs
027-725 Extension Server Operation RAP
Job operation of the application interface failed.
Procedure
•
Check the destination host of the application interface and then repeat the operation.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 6
,
GP 16
)
027-726 Extension Server State RAP
The status of the destination of the application interface is unknown.
Procedure
•
Check the destination host of the application interface and then repeat the operation.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 6
,
GP 16
)