BUS Updated 12/2011
07/2011
2-810
WorkCentre 5335 Family Service Documentation
077-307, 077-308
Initial Issue
Status Indicator RAPs
077-307 Duplex Cover Open RAP
BSD-ON:
BSD 1.8 - Power Interlock Switching (1 of 2)
The Duplex Cover is open.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Duplex Cover for damage or mismatch.
•
The Duplex Cover Switch for failure:
Component Control
[077-305] (
PL 14.4
)
•
The connection between the Duplex Cover Switch
P/J108
and the MCU PWB
P/J409
for
open circuit, short circuit, and poor contact
Reload the machine software (
GP 16
). If no problems are found, replace the MCU PWB (
PL
18.2
).
077-308 L/H Upper Cover Open RAP
BSD-ON:
BSD 1.8 - Power Interlock Switching (1 of 2)
The L/H High Cover is open.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The L/H High Cover Assembly for damage or mismatch
•
The L/H High Cover Switch for failure:
Component Control
[077-302] (
PL 17.4
)
•
Turn the power OFF. Check the connection between the L/H High Cover Switch
P/J116
and the MCU PWB
P/J409
for open circuit, short circuit, and poor contact
Reload the machine software (
GP 16
). If no problems are found, replace the MCU PWB (
PL
18.2
).