BUS Updated 12/2011
07/2011
2-85
WorkCentre 5335 Family Service Documentation
010-421, 010-398
Status Indicator RAPs
Initial Issue
010-421 Fuser End Of Life
Fuser at end of life.
Procedure
Replace the Fuser Assembly (
PL 7.1
) and reset the HFSI Value (
HFSI Counter
) [954-850].
010-398 Fuser Fan Fault RAP
BSD-ON:
BSD 10.2 - Fusing
Fan (for air exhaust around the Fuser) rotation failure.
Procedure
Execute
Component Control
for the Fuser Fan [042-006]. The Fuser Fan rotates.
Y
N
Check the wires between
P/J210
on the Fuser Fan and
P/J411
on the MCU PWB for an
open or shorted circuit, or a loose or damaged connector. The wires are OK.
Y
N
Repair as required.
Replace the Fuser Fan (
PL 4.1
) before replacing the MCU PWB (
PL 18.2
)
Check the wire between
P/J210
-3 on the Fuser Fan and
P/J411
-B12 on the MCU PWB for an
open circuit. If OK, replace the MCU PWB (
PL 18.2
).