WorkCentre 5335 Family Service Documentation
116-325, 116-328
Status Indicator RAPs
Initial Issue
116-325 ESS Fan RAP
The ESS fan failed.
Procedure
Turn the power OFF then ON. Replace the ESS fan (
PL 35.2
).
116-328 L2 Cache Fail RAP
A failure was detected in the Level 2 Cache built in the CPU.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)