BUS Updated 12/2011
07/2011
2-168
WorkCentre 5335 Family Service Documentation
016-367, 016-368
Initial Issue
Status Indicator RAPs
016-367 Cont HDD Fail-2 RAP
BSD-ON:
BSD 16.1 - ESS
Cont HDD Diagnostic Fail-2. An error occurred during W/R/V test of HDD.
Procedure
Turn the power OFF then ON. If the problem persists, perform the following:
•
Disconnect and re-connect the HDD Wire Harness (
PL 35.2
).
•
Check for 5VDC between
P/J302
-1 (red) and
P/J302
-3 (blk) on the HDD.
•
Check the sw version of the controller sw - update if required
•
Replace the HDD and the HDD Wire Harness (
PL 35.2
).
•
Replace the ESS PWB (
PL 35.2
).
016-368 Cont Thumbnail Fail RAP
BSD-ON:
BSD 16.1 - ESS
Cont Diagnostic Fail. An error occurred during W/R/V test of PCI Config interval or W/R/V test
of internal register.
Procedure
NOTE:
Turn the power OFF then ON. If the problem persists, perform the following
•
Replace the ESS PWB (
PL 35.2
). Check the sw version of the controller sw - update if
required.