BUS Updated 12/2011
07/2011
2-758
WorkCentre 5335 Family Service Documentation
041-329, 041-330
Initial Issue
Status Indicator RAPs
041-329 MCU PWB F6 Open RAP
BSD-ON:
BSD 1.9 - Power Interlock Switching (2 of 2)
BSD-ON:
BSD 1.7 - DC Power Distribution (options)
Fuse 6 on the MCU PWB has blown.
NOTE: Remove the cause of Fuse meltdown before replacing the MCU PWB.
When turning the power OFF, turn OFF the power switch first and then the main power switch.
CAUTION
Chip fuses on the MCU PWB seldom fail because of an internal MCU problem. The cause is
almost always a short circuit in the wiring or components fed by the fuse. You MUST determine
the source of the short before replacing the MCU PWB.
Procedure
1.
Check the Tray Module PWB (
PL 11.13
) c24 Volt
IOT wirenets
for overcurrent and
overvoltage, and then replace the faulty parts or repair the circuits.
2.
Turn the power OFF and replace the MCU PWB (
PL 18.2
).
041-330 MCU PWB F7 Open RAP
BSD-ON:
BSD 1.9 - Power Interlock Switching (2 of 2)
BSD-ON:
BSD 1.7 - DC Power Distribution (options)
,
BSD-ON:
BSD 12.1 - Integrated Finisher DC Power and Interlock Switching
,
Fuse 7 on the MCU PWB has blown.
NOTE: Remove the cause of Fuse meltdown before replacing the MCU PWB.
When turning the power OFF, turn OFF the power switch first and then the main power switch.
CAUTION
Chip fuses on the MCU PWB seldom fail because of an internal MCU problem. The cause is
almost always a short circuit in the wiring or components fed by the fuse. You MUST determine
the source of the short before replacing the MCU PWB.
Procedure
1.
Check the Finisher PWB (INT) (
PL 22.7
) c24 Volt
IOT wirenets
for overcurrent and
overvoltage, and then replace the faulty parts or repair the circuits.
2.
Turn the power OFF and replace the MCU PWB (
PL 18.2
).