BUS Updated 12/2011
07/2011
2-642
WorkCentre 5335 Family Service Documentation
034-789, 034-790
Initial Issue
Status Indicator RAPs
034-789 G4 Presentation Illegal Event RAP
BSD-ON:
BSD 34.1 - FAX
There is a presentation of an illegal event.
Procedure
•
Check the remote machine settings and line status, then perform the operation again.
•
Ask customer to cancel the job and resend.
•
Check the Fax line connection (telephone line).
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWBs in the FAX Module
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the FAX PWB (
PL 18.5
).
034-790 Line 0 (Ext) not Connected RAP
BSD-ON:
BSD 34.1 - FAX
Channel 0 outside line is not connected.
Procedure
•
Check the remote machine settings and line status, then perform the operation again.
•
Ask customer to cancel the job and resend.
•
Check the Fax line connection (telephone line).
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWBs in the FAX Module
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the FAX PWB (
PL 18.5
).