BUS Updated 12/2011
07/2011
2-245
WorkCentre 5335 Family Service Documentation
016-732, 016-733
Status Indicator RAPs
Initial Issue
016-732 Form Not Registered RAP
The decomposer detected that the form specified in emulation is not registered.
Initial Actions
Power Off/On
Procedure
•
Rerun the job.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
016-733 Destination Address RAP
There is an error in the destination address. A failure to resolve a P2P address problem (before
connection to the server).
1.
When E-mails are sent using Peer-to-peer communication, an IP address could not be
obtained from the text on the right side of @ in the destination E-mail address.
2.
When E-mails are sent using Peer-to-peer communication, DNS cannot be resolved with
the text on the right side of @ in the destination E-mail address as FQDN.
Initial Actions
Power Off/On
Procedure
1.
Check if the destination address has been entered properly.
2.
Set a correct DNS server address.
If the problem persists, perform the following procedures in sequence to repair it.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firm-
ware module, EEPROM)
•
Check the sw version of the controller sw - update if required