BUS Updated 12/2011
07/2011
4-41
WorkCentre 5335 Family Service Documentation
REP 6.5
Repairs & Adjustments
Initial Issue
When installing, place it such that the Mark is at the rear.
Figure 2 DADF Platen Glass Mark
6.
Unfasten the Full Rate Carriage from the Carriage Cable (
Figure 3
)
(1) Move the Full Rate Carriage to the notch on the frame.
(2) Remove the screw.
Figure 3 Full Carriage Cable
7.
Remove the Carriage Cable (
Figure 4
)
(1) Remove the spring from the Frame.
(2) Detach the cable from the spring.
Figure 4 Carriage Cable Removal
8.
Remove the Carriage Cable (
Figure 5
)
(1) Pull out the ball from the notch of the Frame and remove the Carriage Cable.
Figure 5 Carriage Cable Ball
Replacement
1.
Insert the ball of the Carriage Cable into the groove of the pulley (
Figure 6
)