BUS Updated 12/2011
07/2011
2-825
WorkCentre 5335 Family Service Documentation
091-406, 091-600
Status Indicator RAPs
Initial Issue
091-406 Drum Cartridge Pre Near Life RAP
It was detected that the replacement timing for Drum is closer than Near.
Procedure
The Drum needs to be replaced soon. Replace the Drum (
PL 8.1
) as required.
091-600 Temperature Sensor Fail RAP
BSD-ON:
BSD 9.4 - Transfer
Environment Temp Sensor failure.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Temperature Sensor for failure:
Component Control
[092-200] (
PL 8.2
).
•
The connection between the Hum and Temp Sensor
P/J150
and the MCU PWB
P/J415
for open circuit, short circuit, and poor contact
If no problems are found, reload the machine software (
GP 16
).