BUS Updated 12/2011
07/2011
2-960
WorkCentre 5335 Family Service Documentation
124-316, 124-317
Initial Issue
Status Indicator RAPs
124-316 Product Mode RAP
BSD-ON:
BSD 3.8 - Electronic Billing
There is an error in product mode of operation.
Procedure
Turn the power OFF then ON. If the problem persists, perform the following procedure to
repair it.
Reload software
GP 16
. Replace the MCU PWB (
PL 18.2
) and the ESS PWB (
PL 35.2
).
Go to
Machine ID/Billing Data
.
124-317 All Product Mode RAP
BSD-ON:
BSD 3.8 - Electronic Billing
There is an error in all modes of product operation.
Procedure
Turn the power OFF then ON. Execute
NVM Read/Write
. Compare the values in the following
NVM locations:
[700-600]
[700-601]
[700-602]
The 3 values match.
Y
N
Go to
Machine ID/Billing Data
.
Reload software
GP 16
. Replace the MCU PWB (
PL 18.2
) and the ESS PWB (
PL 35.2
).