General Lists
Name
Description
Profibus.Data OK
Data within the Input field are OK (Yes=1)
Profibus.SubModul Err
Assignable Signal, Failure in Sub-Module, Communication Failure.
Profibus.Connection
active
Connection active
Profibus.Scada Cmd 1
Scada Command
Profibus.Scada Cmd 2
Scada Command
Profibus.Scada Cmd 3
Scada Command
Profibus.Scada Cmd 4
Scada Command
Profibus.Scada Cmd 5
Scada Command
Profibus.Scada Cmd 6
Scada Command
Profibus.Scada Cmd 7
Scada Command
Profibus.Scada Cmd 8
Scada Command
Profibus.Scada Cmd 9
Scada Command
Profibus.Scada Cmd 10
Scada Command
Profibus.Scada Cmd 11
Scada Command
Profibus.Scada Cmd 12
Scada Command
Profibus.Scada Cmd 13
Scada Command
Profibus.Scada Cmd 14
Scada Command
Profibus.Scada Cmd 15
Scada Command
Profibus.Scada Cmd 16
Scada Command
ProtCom.active
Signal: active
ProtCom.inactive
Signal: inactive
ProtCom.ExBlo
Signal: External Blocking
ProtCom.Blo forced
Protection-communication is temporarily forced to be deactivated (blocked).
ProtCom.Qual.Warn.
Error Rate is above warning level.
ProtCom.Comm.Ok
Protection-communication Ok. Measuring systems is synchron with remote device.
ProtCom.FrameSync
Frames are synchronized.
ProtCom.TimeSync
Internal time bases are synchronized.
ProtCom.Loopback
Device is in Loopback-mode.
ProtCom.ExBlo1-I
Module input state: External blocking1
ProtCom.ExBlo2-I
Module input state: External blocking2
IRIG-B.IRIG-B active
Signal: If there is no valid IRIG-B signal for 60 sec, IRIG-B is regarded as inactive.
IRIG-B.High-Low Invert
Signal: The High and Low signals of the IRIG-B are inverted. This does NOT mean that
the wiring is faulty. If the wiring is faulty no IRIG-B signal will be detected.
IRIG-B.Control Signal1
Signal: IRIG-B Control Signal. The external IRIG-B generator can set these signals.
They can be used for further control procedures inside the device (e.g. logic
funtions).
IRIG-B.Control Signal2
Signal: IRIG-B Control Signal. The external IRIG-B generator can set these signals.
They can be used for further control procedures inside the device (e.g. logic
funtions).
1217
MCDLV4
DOK-HB-MCDLV4-2E
Summary of Contents for HighPROtec MCDLV4
Page 3: ...Order Code Order Code 3 MCDLV4 DOK HB MCDLV4 2E...
Page 47: ...Installation and Connection 47 MCDLV4 DOK HB MCDLV4 2E...
Page 164: ...Input Output and LED Settings 164 MCDLV4 DOK HB MCDLV4 2E...
Page 433: ...Parameters 433 MCDLV4 DOK HB MCDLV4 2E...
Page 457: ...Device Parameters 457 MCDLV4 DOK HB MCDLV4 2E...
Page 473: ...Blockings 473 MCDLV4 DOK HB MCDLV4 2E...
Page 988: ...Protective Elements 988 MCDLV4 DOK HB MCDLV4 2E P P Q P Q P Q Q Q P S S...
Page 989: ...Protective Elements 989 MCDLV4 DOK HB MCDLV4 2E Pr Q P Q P Qr...
Page 1023: ...Protective Elements 1023 MCDLV4 DOK HB MCDLV4 2E...