Thank you for choosing Panamax.

The MAX

®

4400-20A is designed to

provide AC power distribution and

maximum protection for audio/

video equipment.

Inductorless Noise Filtration

Capacitive noise filtration allows

amplifiers and powered sub-

woofers to perform to their full

potential.  When the movie thun-

ders with a terrific explosion or

when the music reaches a climac-

tic crescendo, an amplifier has to

rapidly draw large amounts of cur-

rent to replenish its power supply

capacitors.  Traditional line condi-

tioners impede this current draw,

in effect, starving an amplifier and

resulting in a flat, dead sound.

The MAX

®

4400 20A provides clean,

filtered power to amplifiers but has

no current-limiting components to

impede performance.

INSTALLING THE MAX

®

 4400-20A

NOTE:

The MAX

®

4400-20A and the

connected equipment must be

indoors and in the same building.

1

. Plug the MAX

®

4400-20A directly

into a properly grounded 3-wire

AC outlet*.

2

. Turn the MAX

®

4400-20A on.

3

. Plug in one of the pieces of

equipment you want to protect and

turn the equipment on.

If the equipment is working cor-

rectly, continue to plug in and turn

on your equipment.

In the extremely unlikely event that

everything does not work perfectly,

stop and read the troubleshooting

section. If you continue to have

problems, call PANAMAX

Customer Relations Department at

800-472-5555

, USA and Canada. 

*Many old buildings are inade-

quately wired. It is very common

for a building to be improperly

grounded. Building wiring and

grounding must conform to appli-

cable NEC (USA) or CEC (Canada)

codes for the PANAMAX connect-

ed equipment policy to be valid.

TROUBLESHOOTING

There is no AC power to my

equipment, or my equipment

doesn’t turn on

.

Make sure that the MAX

®

4400-20

is plugged into a working AC outlet.

Check all AC connections.

Make sure the MAX

®

4400-20A and

connected equipment is turned on.

If you are using the 12VDC trigger,

make sure that the source is actu-

ally supplying the voltage needed

to activate the MAX

®

4400-20A.

Check to see if the circuit breaker

on the MAX

®

4400-20A needs to be

reset (press in).

The MAX

®

4400-20A circuit breaker

disconnects AC power from the

connected equipment.

You have exceeded the ampere rat-

ing for your surge protector.

As a temporary fix, disconnect one

or more pieces of equipment. Ask

your dealer about additional PANA-

MAX products that may be

required.

If you continue to have trouble

with your MAX

®

4400-20A or this  

section has not fixed the problem,

please call PANAMAX Customer

Relations Department at 

800-472-5555.

CONTACTING PANAMAX

For product and warranty informa-

tion, dealer information, and other

general information contact

Customer Relations at:

Email:

[email protected]

Web:

www.panamax.com

Fax:

707-283-5901

Phone:

800-472-5555

or

707-283-5900

,

7:30 a.m.- 5 p.m.PST

MAX

®

4400 20A PRODUCT SPECIFICATIONS

AC Surge Protection

Line Voltage……………......……………….120V, 50/60 Hz

Maximum Current Rating…….......................………….20A

UL 1449 Surge Suppression Rating…...................……330V

Protection Modes…………………….......…..L-N, L-G, N-G

Initial Clamping Level………........….200V Peak, 141V RMS

Response Time………...........................……………...<1ns

Joule Rating……………………............………1650 Joules

Peak Impulse Current……...........................………52,000A

EMI/RFI Noise Filtration……......…. 50dB (100KHz - 1 MHz)

Catastrophic Surge Circuit……......................………….YES

Thermal Fusing……...................……………………….YES

Over/Under Voltage Protection……....................………YES

Over-voltage shutoff threshold…………..............…147V ±8

Under-voltage shutoff threshold……..................……84V±6

DC Trigger

Connection………………….............……3.5mm mini-plug

Voltage and Polarity……..................5-30VDC, bi-directional

Current Requirement….......................…………...…>10mA

INS4400 20A REV. A       11/02

20A Circuit Breaker 

- will

automatically “open” when

the current load is greater

than 20 Amperes. When

this happens, the circuit

breaker can be manually

reset by simply pushing 

the reset button, which 

will have “popped” out.”

Always-On Outlets

- Four

Always-On outlets provide

a constant power source.

Ground Lug

-

Provides a common

grounding point for

equipment with

separate ground

Switched Outlets

-

Four outlets controlled

by one of the two trig-

ger sources.

Voltage Sense Trigger

Input

- 3.5mm Mini-

Plug jack. Connect to a

remote trigger device

that provides 12VDC to

trigger a startup/ shut-

down sequence. This is

the second trigger that

will turn-on or turn-off

the switched outlets. 

Turn-On Delay

Switch

- Provides

a 10-second

Turn-On delay 

for the switched

outlets.

Switched Outlets Pushbutton 

-

one of two triggers that can

turn-on or turn-off the switched

outlets. Leave this switch in the

ON position if the DC trigger is

being used.

Ground OK LED

-

(green) indicates that

the wall outlet is

properly grounded.

Unsafe Voltage

- (red) when lit, indicates

that incoming voltage is unsafe and the

surge protector has disconnected the

power to protect your equipment.

Voltage Trigger LED

-

(green) when lit, indicates

that the DC Trigger is

active (ON).

Switched Outlets LED

-

Indicates that the

Switched Outlets 

are on.

Always-on Convenience Outlet

-

10 Ft. AC Power Cord

-

1690 Corporate Circle, Petaluma, 94954 • Phone 707-283-5900 • Toll Free 800-472-5555 • Fax 707-283-5901 • www.panamax.com

Reviews: