Analysis > P Pointer
For TV pointers:
Pointer value
LOP (Loss of Pointer)
PJE and NJE
NDF or New Data Flags
Difference and Sum
Analysis > VT tab
10.2.4.2 Point Generator
The Pointer generator is able to generate individual pointer movements as follows:
For STS pointers:
SS bits: Program bits 5 and 6 of the H1 byte to be either SONET [10], SONET [00], Unknown [01] or
[11].
Pointer value: Transmits a new pointer address or value with or without a new data flag (NDF).
Configurable in a range of 0 to 782 pointers.
Increment (INC) or Decrement (DEC) pointers with identical polarity by 1 byte in single steps.