Pointer Sequence Testing
It is recommended to run one sequence with positive adjustments followed by a
sequence with negative adjustments. Performing the measurement at the maximum
positive and negative frequency offset applicable to the line rate increases the stress on
the pointer processor.
The test procedure includes an initialization period followed by a cool down period of
30 seconds with no pointer movements.
10.2.5 Trace Identifier
Tap the
Trace Identifier
icon to display the path trace testing screens shown below. There are dedicated tabs for
Transmitted and Received (expected) path traces and setups.
SDH/SONET Tools Menu
10.2.5.1 Transmitted Traces (TX)
J0 [Section]: Regenerator section trace
Program a 1 or 16-byte identifier to check the connection between regenerators
J1 [STS Path]: High order path section trace
Program a 16 or 64-byte identifier to check the high order transmission path
The message is transmitted one byte per STS-3 frame
J2 [VT Path]: Low order path section trace
Program a 16 or 64-byte identifier to check the low order transmission path
To program or edit the transmitted trace, tap the applicable trace box to display the pop-up keyboard.
RXT-6200_RXT6000e_Module_Manual
Page 168 of 387
Summary of Contents for RXT-6000e
Page 1: ......
Page 39: ...Rx Pattern Setup Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 39 of 387...
Page 48: ...Tx Interface Setup Tx Structure Setup Text Mode RXT 6200_RXT6000e_Module_Manual Page 48 of 387...
Page 61: ...RXT 6200_RXT6000e_Module_Manual Page 61 of 387...
Page 97: ...RXT 6200_RXT6000e_Module_Manual Page 97 of 387...
Page 199: ...RXT 6200_RXT6000e_Module_Manual Page 199 of 387...
Page 267: ...Event Log Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 267 of 387...
Page 327: ...Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 327 of 387...
Page 351: ...Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 351 of 387...