available when Rx is optical and Tx is in PDH mode, (i.e. a Mux).
6.6.4 Auto-Config
The Auto-Configuration function is described below.
Auto-config tab
The
Auto-Config
function automatically sets the receiver of the test set. A search for SDH and PDH signals at both
the electrical or optical inputs is performed to determine the signal structure. For electrical signals, both Terminated
and PMP voltage ranges are searched and supported.
Procedure
Tap on the
Start
button
to begin the search. The received signal is checked for network type, hierarchy
and bit rate, payload structure, payload framing, test pattern and signal level. If the search is successful, a “
PASS
”
result is displayed.
Search parameters and criteria
Interface:
Checks physical parameters (bit rate line code).
Mapping:
Checks mapping structure using the signal label and pointer bytes.
Payload:
Only test patterns defined in ITU-T or ANSI standards will be recognized. If no test pattern is
detected, the unit assumes live traffic.
PDH Signals:
Unframed or framed payloads at all hierarchies. For 1.5M signals containing 64kbps timeslots, the test
set will assume live traffic and will not search for a test pattern.
RXT-6200_RXT6000e_Module_Manual
Page 56 of 387
Summary of Contents for RXT-6000e
Page 1: ......
Page 39: ...Rx Pattern Setup Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 39 of 387...
Page 48: ...Tx Interface Setup Tx Structure Setup Text Mode RXT 6200_RXT6000e_Module_Manual Page 48 of 387...
Page 61: ...RXT 6200_RXT6000e_Module_Manual Page 61 of 387...
Page 97: ...RXT 6200_RXT6000e_Module_Manual Page 97 of 387...
Page 199: ...RXT 6200_RXT6000e_Module_Manual Page 199 of 387...
Page 267: ...Event Log Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 267 of 387...
Page 327: ...Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 327 of 387...
Page 351: ...Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 351 of 387...