RFC 2544 Setup - Latency Settings
Frame Loss tab:
Max Rate:
Up to 100% of the negotiated line rate. The default value is 100%.
This is the maximum transmit rate to perform the frame loss test for each test frame size. The user may
configure this rate as a % of the total line rate or in Mbps. For example if the user configures the Max Rate to be
90% and the negotiated line rate of the link is 100Mbps, then the maximum transmit rate will be 90Mbps or
90% of the line rate.
Step Size:
1 to 10%. The default value is 10%.
The step size is the rate % that the frame loss test will be reduced by in the event of any frame loss. For example
if the Max Rate is 100Mbps (or 100%) and frames are lost at this rate, then the transmit rate will be reduced to
90Mbps (or 90%). The frame loss test will now be performed at the new rate until there is zero frame loss at two
consecutive rate settings. This means that the test will have to be performed at 80% (assuming that there was
zero frame loss at 90%).
Duration:
Selectable in the range 5 to 999 seconds. The default value is 20 seconds.
The duration is the amount of time the throughput test is run for, for each frame size at a given rate.
RFC 2544 Setup - Frame Loss Settings
RXT-6200_RXT6000e_Module_Manual
Page 241 of 387
Summary of Contents for RXT-6000e
Page 1: ......
Page 39: ...Rx Pattern Setup Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 39 of 387...
Page 48: ...Tx Interface Setup Tx Structure Setup Text Mode RXT 6200_RXT6000e_Module_Manual Page 48 of 387...
Page 61: ...RXT 6200_RXT6000e_Module_Manual Page 61 of 387...
Page 97: ...RXT 6200_RXT6000e_Module_Manual Page 97 of 387...
Page 199: ...RXT 6200_RXT6000e_Module_Manual Page 199 of 387...
Page 267: ...Event Log Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 267 of 387...
Page 327: ...Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 327 of 387...
Page 351: ...Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 351 of 387...