Error Message: Configuration Suggestions
Loss of Signal (LOS) Check
If the LOS condition is detected at any time during the MTJ test, the data will become invalid and the test will stop
automatically. An error message will appear to notify the user to correct the condition before running the test again.
LOS Error Message
Table
Table values include:
Frequency tested (Hz)
MTJ (UI):
Maximum Tolerable Jitter (in Unit Intervals).
Mask (UI):
Peak-to-Peak jitter limit (in UI) as defined by ITU standard. This is the minimum jitter value to pass
(i.e., the MTJ value must exceed the Mask value for the data point to pass).
Status:
Pass/Fail status.
Start/Stop:
Starts or stops the test.
Progress:
A green bar at the bottom of the graph shows the test progress.