G.873 > TU tab
Pointer Sequence Testing
It is recommended to run one sequence with positive adjustments followed by a
sequence with negative adjustments. Performing the measurement at the maximum
positive and negative frequency offset applicable to the line rate increases the stress on
the pointer processor.
The test procedure includes an initialization period followed by a cool down period of
30 seconds with no pointer movements.
10.1.5 Trace Identifier
Tap the
Trace
Identifier icon to display the path trace testing application and screens.
SDH/SONET Tools Menu
RXT-6200_RXT6000e_Module_Manual
Page 138 of 387