Changing the active group
•
Press 1 (= Change active group) to display the "Change active group" screen.
/ 3
C h a n g e
a c t i v e
g r o u p ( A c t i v e
g r o u p =
* )
1 = G r o u p 1
2 = G r o u p 2
3 = G r o u p 3
4 = G r o u p 4
5 = G r o u p 5
6 = G r o u p 6
7 = G r o u p 7
8 = G r o u p 8
C u r r e n t
N o . =
*
S e l e c t
N o .
=
•
Enter the selected number and press the ENTER key.
Changing the settings
Almost all the setting items have default values that are set when the product was shipped. For the
default values, see Appendix D and H.
To change the settings, do the following:
•
Press 2 (= Change setting) to display the "Change setting" screen.
/ 3
C h a n g e
s e t t i n g
( A c t i v e
g r o u p =
* )
1 = G r o u p 1
2 = G r o u p 2
3 = G r o u p 3
4 = G r o u p 4
5 = G r o u p 5
6 = G r o u p 6
7 = G r o u p 7
8 = G r o u p 8
•
Press the group number to change the settings and display the "Protection" screen. (In model
100 series, 3 = Autoreclose is not displayed.)
/4 Protection (Group *)
1=Line parameter
2=Trip
3=Autoreclose
Setting the line parameters
Enter the line name, VT&CT ratio and settings for the fault locator as follows:
•
Press 1 (= Line parameter) on the "Protection" screen to display the "Line parameter" screen.
/ 5
L i n e
p a r a m e t e r
( G r o u p
* )
1 = L i n e
n a m e
2 = V T
&
C T
r a t i o
3 = F a u l t
l o c a t o r
•
Press 1 (= Line name) to display the "Line name" screen.
•
Enter the line name as a text string.
•
Press
the END key to return the display to the "Line parameter" screen.
•
Press 2 (= VT&CT ratio) to display the "VT&CT ratio" screen.
Summary of Contents for GRZ100 B Series
Page 264: ... 263 6 F 2 S 0 8 4 6 Appendix A Block Diagram ...
Page 271: ... 270 6 F 2 S 0 8 4 6 ...
Page 272: ... 271 6 F 2 S 0 8 4 6 Appendix B Signal List ...
Page 307: ... 306 6 F 2 S 0 8 4 6 ...
Page 308: ... 307 6 F 2 S 0 8 4 6 Appendix C Variable Timer List ...
Page 310: ... 309 6 F 2 S 0 8 4 6 Appendix D Binary Input Output Default Setting List ...
Page 321: ... 320 6 F 2 S 0 8 4 6 ...
Page 322: ... 321 6 F 2 S 0 8 4 6 Appendix E Details of Relay Menu and LCD Button Operation ...
Page 331: ... 330 6 F 2 S 0 8 4 6 ...
Page 340: ... 339 6 F 2 S 0 8 4 6 Appendix G Typical External Connections ...
Page 377: ... 376 6 F 2 S 0 8 4 6 ...
Page 384: ... 383 6 F 2 S 0 8 4 6 Appendix J Return Repair Form ...
Page 388: ... 387 6 F 2 S 0 8 4 6 Customer Name Company Name Address Telephone No Facsimile No Signature ...
Page 389: ... 388 6 F 2 S 0 8 4 6 ...
Page 390: ... 389 6 F 2 S 0 8 4 6 Appendix K Technical Data ...
Page 401: ... 400 6 F 2 S 0 8 4 6 ...
Page 402: ... 401 6 F 2 S 0 8 4 6 Appendix L Symbols Used in Scheme Logic ...
Page 405: ... 404 6 F 2 S 0 8 4 6 ...
Page 406: ... 405 6 F 2 S 0 8 4 6 Appendix M Example of Setting Calculation ...
Page 417: ... 416 6 F 2 S 0 8 4 6 ...
Page 418: ... 417 6 F 2 S 0 8 4 6 Appendix N IEC60870 5 103 Interoperability and Troubleshooting ...
Page 434: ... 433 6 F 2 S 0 8 4 6 Appendix P Inverse Time Characteristics ...
Page 437: ... 436 6 F 2 S 0 8 4 6 ...
Page 438: ... 437 6 F 2 S 0 8 4 6 Appendix Q Failed Module Tracing and Replacement ...
Page 444: ... 443 6 F 2 S 0 8 4 6 Appendix R Ordering ...
Page 447: ......