Installation Instructions

NOTE: 

Read this entire instruction manual before starting the installation.

SAFETY CONSIDERATIONS

Improper  installation,  adjustment,  alteration,  service,  maintenance,  or

use can cause explosion, fire, electrical shock, or other conditions which

may  cause  death,  personal  injury  or  property  damage.  Consult  a

qualified  installer,  service  agency,  or  your  distributor  or  branch  for

information  or  assistance.  The  qualified  installer  or  agency  must  use

factory-authorized  kits  or  accessories  when  modifying  this  product.

Refer to individual instructions packaged with kits or accessories when

installing.

Follow  all  safety  codes. Wear  safety  glasses,  protective  clothing,  and

work gloves.  Use  quenching cloth  for  brazing  operations.  Have a fire

extinguisher available. Read these instructions thoroughly and follow all

warning  or  cautions  included  in  literature  and  attached  to  the  unit.

Consult  local  building  codes  and  the  current  editions  of  the  National

Electrical Code (NEC) NFPA 70.

In Canada, refer to the current editions of Canadian Electrical Code CSA

C22.1.
Recognize safety information. This is the safety alert symbol  . When

you see this symbol on the unit and in instructions or manuals, be alert to

the  potential  for  personal  injury.  Understand  the  signal  words

DANGER

WARNING

, and 

CAUTION

. These words are used with the

safety alert symbol. 

DANGER

 identifies the most serious hazards which

will  result  in  severe  personal  injury  or  death. 

WARNING

  signifies

hazards  which  could  result  in personal  injury  or  death. 

CAUTION

 is

used  to  identify  unsafe  practices, which  may  result  in  minor personal

injury  or  product  and  property  damage. 

NOTE

  is  used  to  highlight

suggestions  which  will  result  in  enhanced  installation,  reliability,  or

operation.

HN72ZA001 Kit Contents

• Current Sensing Relay

• Conduit Fitting

• Wire Nuts

Tools Required

• Small cross-head screwdriver

INSTALLATION

IMPORTANT: 

This  kit  is  intended  for 

ceiling-mounted

  air  purifier

units (RGAPA) 

only

. If your unit is mounted next to the furnace or fan

coil (DGAPA or PGAPA), discard this kit.

Mounting to Fan Coil Air Handlers

IMPORTANT: 

Power connections  are  to be made inside the fan  coil

wiring compartment per local electrical codes, and the two in-line fuses

that are provided with the air purifier must be installed in the fan coil

wiring compartment.

1. Disconnect main power to the unit and lock out / tag.
2. Open the ceiling grille cover, lower the inner unit, and remove the

filter cartridge and FEM. If necessary, refer to the Installation and

User Instructions.

3. From the top of the air purifier, accessible in the space above the

ceiling, remove the access cover from the RGAPA electrical box.

4. Route the power wiring from the purifier disconnect to a knockout

on  the  fan  coil  air  handler  that  provides  access  to  the  incoming

power wiring compartment. Affix the end of the conduit to the fan

coil air handler using the included conduit fitting.

5. Remove the yellow and black primary wires from the fan coil air

handler  transformer  terminals  and  connect  the  quick-connect

"piggyback" terminals of the quick-connect kit leads exiting the air

purifier power conduit assembly to the transformer terminals.

6. Reconnect the yellow and black primary wires to their respective

transformer terminals on the "piggyback" terminals.

7. Attach the ground ring terminal on the third wire to the fan coil air

handler chassis ground 

(Fig. 1)

.

HN72ZA001
Quick Connect Kit and Current Sensing Relay

for RGAPA Ceiling-Mounted Return Air Purifier

WARNING

!

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing or servicing the unit, always turn off all power to unit.

There  may  be  more  than  one  disconnect  switch.  Lock  out  and  tag

switch with a suitable warning label.

CAUTION

!

CUT HAZARD

Failure to follow this caution may result in personal injury. 
Sheet metal parts may have sharp edges or burrs. Use care and wear

appropriate  protective  clothing,  safety  glasses  and  gloves  when

handling parts.

CAUTION

!

UNIT COMPONENT DAMAGE HAZARD

Failure  to  follow  this  caution  may  result  in  equipment  damage  or

improper operation.

For Furnace Purifiers:

-

Black Lead connect to Hot (L1) or EAC-1 when provided.

-

White Lead connect to Neutral (L2) or EAC-2 when provided.

-

Green/Ground Lead connect to appliance ground (chassis).

For Fan Coil Purifiers:

-

Black Lead connect to L1.

-

White Lead connect to L2.

-

Green Lead connect to appliance ground (chassis).