422
⎯
6
F
2
S
0
8
4
6
IEC103 configurator Default setting
INF
Description
Contents
GI
Type
ID
COT
FUN Max. No.
Measurands
144 Measurand I
<meaurand I>
No
0
145 Measurand I,V
<meaurand I>
No
0
146 Measurand I,V,P,Q
<meaurand I>
No
0
147 Measurand IN,VEN
<meaurand I>
No
0
148
Measurand IL1,2,3, VL1,2,3,
P,Q,f
Ia, Ib, Ic, Va, Vb, Vc, P, Q, f measurand
<meaurand II>
--
9
2, 7
128
9
Generic Function
240 Read Headings
Not supported
241
Read attributes of all entries
of a group
Not supported
243 Read directory of entry
Not supported
244 Real attribute of entry
Not supported
245 End of GGI
Not supported
249 Write entry with confirm
Not supported
250 Write entry with execute
Not supported
251 Write entry aborted
Not supported
Details of MEA settings in IEC103 configurator
INF MEA
Tbl
Offset Data type
Limit
Coeff
Lower
Upper
148
Ia
1
36
short
0
4096
3.41333
Ib
1
40
short
0
4096
3.41333
Ic
1
44
short
0
4096
3.41333
Va
1
0
short
0
4096
0.26877
Vb
1
4
short
0
4096
0.26877
Vc
1
8
short
0
4096
0.26877
P
2
8
long
-4096
4096
0.00071661
Q
2
12
long
-4096
4096
0.00071661
f
2
16
short
0
4096
0.34133
Summary of Contents for GRZ100 B Series
Page 264: ... 263 6 F 2 S 0 8 4 6 Appendix A Block Diagram ...
Page 271: ... 270 6 F 2 S 0 8 4 6 ...
Page 272: ... 271 6 F 2 S 0 8 4 6 Appendix B Signal List ...
Page 307: ... 306 6 F 2 S 0 8 4 6 ...
Page 308: ... 307 6 F 2 S 0 8 4 6 Appendix C Variable Timer List ...
Page 310: ... 309 6 F 2 S 0 8 4 6 Appendix D Binary Input Output Default Setting List ...
Page 321: ... 320 6 F 2 S 0 8 4 6 ...
Page 322: ... 321 6 F 2 S 0 8 4 6 Appendix E Details of Relay Menu and LCD Button Operation ...
Page 331: ... 330 6 F 2 S 0 8 4 6 ...
Page 340: ... 339 6 F 2 S 0 8 4 6 Appendix G Typical External Connections ...
Page 377: ... 376 6 F 2 S 0 8 4 6 ...
Page 384: ... 383 6 F 2 S 0 8 4 6 Appendix J Return Repair Form ...
Page 388: ... 387 6 F 2 S 0 8 4 6 Customer Name Company Name Address Telephone No Facsimile No Signature ...
Page 389: ... 388 6 F 2 S 0 8 4 6 ...
Page 390: ... 389 6 F 2 S 0 8 4 6 Appendix K Technical Data ...
Page 401: ... 400 6 F 2 S 0 8 4 6 ...
Page 402: ... 401 6 F 2 S 0 8 4 6 Appendix L Symbols Used in Scheme Logic ...
Page 405: ... 404 6 F 2 S 0 8 4 6 ...
Page 406: ... 405 6 F 2 S 0 8 4 6 Appendix M Example of Setting Calculation ...
Page 417: ... 416 6 F 2 S 0 8 4 6 ...
Page 418: ... 417 6 F 2 S 0 8 4 6 Appendix N IEC60870 5 103 Interoperability and Troubleshooting ...
Page 434: ... 433 6 F 2 S 0 8 4 6 Appendix P Inverse Time Characteristics ...
Page 437: ... 436 6 F 2 S 0 8 4 6 ...
Page 438: ... 437 6 F 2 S 0 8 4 6 Appendix Q Failed Module Tracing and Replacement ...
Page 444: ... 443 6 F 2 S 0 8 4 6 Appendix R Ordering ...
Page 447: ......