
⎯
342
⎯
6
F
2
S
0
8
4
6
A3
B3
A4
A5
B4
B5
A6
A7
B6
B7
A8
A9
B8
B9
A10
A11
B11
B10
TB2- A2
A1
B1
B2
A12
B12
RELAY FAILURE
B13
TB2-A13
SIGNAL SEND
(HIGH SPEED RELAY)
COM-B
COM-A
RS485 I/F
TB2-A18
B18
A17
B17
A16
B16
TRIP-B
TRIP-A
TRIP-C
BUS CB
(+)
TRIP-B
TRIP-A
TRIP-C
B14
A12
A13
B13
(+)
TB4- A3
A1
B3
A2
B2
TB4-A14
IRIG-B
BO1
BO2
BO3
BO4
BO5
BO6
BO7
BO8
BO9
BO10
BO11
BO12
BO13
FAIL
TP-A1
TP-B1
TP-C1
TP-A2
TP-B2
TP-C2
CN1
COM-0V
+5Vdc
0V
B9
(-)
(-)
B4
A5
B5
A6
B6
A7
B7
A8
B8
A9
TB4 -A4
A10
B10
A11
TB2 -A14
B14
B15
A15
BI1
BI10
BI11
BI2
BI8
BI12
BI9
BI5
BI6
BI7
BI3
BI4
BI13
BI14
BI15
BI16
BI17
BI18
IO#1
IO#2
(Single port)
(-)
TB5 -A14
B14
B15
A15
BI19
BI20
BI21
IO#3
Ethernet LAN I/F
(option)
T
IO#3
TB1
TB2
TB4
TB5
VCT
IO#2
IO#1
Terminal Block Arrangement (Rear view)
A18
A1
B18
B1
1
2
19
20
CN1
E
(+)
CB1-C
Disconnector N/C contact
Carrier protection block
External VT failure (EXT VTF)
CB ready condition
Autoreclose block (REC BLOCK)
Indication reset
Main protection ON
EXT trip-A
EXT trip-B
EXT trip-C
(+)
CB1-A
CB auxiliary contacts
(Closed when bus CB main
contact closed.)
CB1-B
Signal receive (CH2)
or Z1-EXT initiation
External trip signals
(CBF Initiation)
Signal receive (CH1)
[Default setting]
Disconnector N/O contact
Main protection trip
DD FAIL.
TB4-A16
(-)
(+)
B18
A18
E
B17
B16
A17
DC
SUPPLY
CASE EARTH
DC-DC
RELAY FAIL.
≧1
B15
A15
(
∗
1)
(
∗
1)These connections are connected
by wire link before shipment.
A3
B3
A4
A5
B4
B5
A6
A7
B6
B7
A8
A9
B8
B9
A10
A11
B11
A12
A13
B12
B10
B13
IO#3
TB5- A2
A1
B1
B2
BO1
BO2
BO3
BO4
BO5
BO6
BO7
BO8
BO9
BO10
BO11
BO12
BO13
BO14
COM2-B
COM2-A
TB2-A18
A17
A16
B18
B17
B16
COM2-0V
COM1-B
COM1-A
COM1-0V
Dual RS485 I/F ports
T
OP1
OP2
For RSM OR IEC103
OP1
T
R
Fibre Optic I/F (option)
For IEC103
OP2
T
R
BUS
TB1 -1
4
3
2
7
6
5
9
8
10
12
11
13
14
BUS VT
VT
From parallel line
Protected line
20
(
∗
1)
(CASE EARTH)
4
3
2
7
6
5
8
TB1- 1
CT
CB
9
10
GRZ100
CT
CB
Parallel line
15
16
BUS VT
For RSM or IEC103
For IEC103
To parallel line
Model 202
IO module
IO#1 IO1
IO#2 IO2
IO#3 IO4
Note: Only terminal blocks used for connections are
shown. (Non-used terminal block TB3 is not shown.)
Summary of Contents for GRZ100 B Series
Page 264: ... 263 6 F 2 S 0 8 4 6 Appendix A Block Diagram ...
Page 271: ... 270 6 F 2 S 0 8 4 6 ...
Page 272: ... 271 6 F 2 S 0 8 4 6 Appendix B Signal List ...
Page 307: ... 306 6 F 2 S 0 8 4 6 ...
Page 308: ... 307 6 F 2 S 0 8 4 6 Appendix C Variable Timer List ...
Page 310: ... 309 6 F 2 S 0 8 4 6 Appendix D Binary Input Output Default Setting List ...
Page 321: ... 320 6 F 2 S 0 8 4 6 ...
Page 322: ... 321 6 F 2 S 0 8 4 6 Appendix E Details of Relay Menu and LCD Button Operation ...
Page 331: ... 330 6 F 2 S 0 8 4 6 ...
Page 340: ... 339 6 F 2 S 0 8 4 6 Appendix G Typical External Connections ...
Page 377: ... 376 6 F 2 S 0 8 4 6 ...
Page 384: ... 383 6 F 2 S 0 8 4 6 Appendix J Return Repair Form ...
Page 388: ... 387 6 F 2 S 0 8 4 6 Customer Name Company Name Address Telephone No Facsimile No Signature ...
Page 389: ... 388 6 F 2 S 0 8 4 6 ...
Page 390: ... 389 6 F 2 S 0 8 4 6 Appendix K Technical Data ...
Page 401: ... 400 6 F 2 S 0 8 4 6 ...
Page 402: ... 401 6 F 2 S 0 8 4 6 Appendix L Symbols Used in Scheme Logic ...
Page 405: ... 404 6 F 2 S 0 8 4 6 ...
Page 406: ... 405 6 F 2 S 0 8 4 6 Appendix M Example of Setting Calculation ...
Page 417: ... 416 6 F 2 S 0 8 4 6 ...
Page 418: ... 417 6 F 2 S 0 8 4 6 Appendix N IEC60870 5 103 Interoperability and Troubleshooting ...
Page 434: ... 433 6 F 2 S 0 8 4 6 Appendix P Inverse Time Characteristics ...
Page 437: ... 436 6 F 2 S 0 8 4 6 ...
Page 438: ... 437 6 F 2 S 0 8 4 6 Appendix Q Failed Module Tracing and Replacement ...
Page 444: ... 443 6 F 2 S 0 8 4 6 Appendix R Ordering ...
Page 447: ......