7.3.11. D
ISASSEMBLING THE ENCODER
Figure 7.3.11-1
Follow the steps described in paragraph 7.3.7.
“Disassembling the Plexiglas weight stack
guard” limited solely to the external part.
1. Release the slot
a
of the ENCODER wire
from the hook.
Figure 7.3.11-2
2. Disconnect the connector
b
of the
ENCODER cable.
3. Use a 4-gauge hexagonal T-wrench to
unscrew the 3 screws
c
.
4. Remove the ENCODER.
Hold the ENCODER up before
unscrewing the last screw.
To replace the ENCODER, follow the above
steps in reverse order.