BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.334
7.8.31. D
ISASSEMBLING THE DOUBLING CABLE
Figure 7.8.31-1
Follow the steps described in paragraph 7.8.18.
“Disassembling the upright guard”.
1. Unscrew the 2 dowels
a
, using a 4-gauge
hexagonal T-wrench.
2. Remove the DOUBLING CABLE with the
aid of a pair of pliers.
3. Unscrew the screw
b
, and the nut
c
using 2
22-gauge wrenches.
4. Remove the DOUBLING CABLE by sliding
it out of the pulleys.
To disassemble the joint:
1. Unscrew the screw
d
using a 17-gauge
wrench.
2. Remove the joint.
To reassemble the DOUBLING CABLE, follow
the above steps in reverse order.
When the operation is complete, adjust
the DOUBLING CABLE tension as
described in paragraph 8.7. .