BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 8.18
Figure 8.2.8-3
4. Adjust the starting position of levers so that
they respect the measurements shown in the
drawing.
5. To do so, adjust the position of the limit
switch by regulating the screw and nut with a
24-gauge wrench.
Figure 8.2.8-4
6. Connect and power all cables.
7. Adjust the stopping position of levers so that
they respect the measurements shown in the
drawing.
8. To do so, adjust the position of the limit
switch by regulating the screw and nut with a
17-gauge wrench.