BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 8.26
8.8. ADJUSTING THE ZERO SENSOR POSITION
This operation is the same for all machines.
Figure 8.8-1
1. Carry out the procedure described in
paragraph 6.1. “Manual Components Test”
until the solenoid of the weight stack
selection brush is in front of the zero sensor.
2. Loosen the nut
a
using a 22-gauge wrench.
3. Move the sensor until it is
3.5 mm
from the
weight stack selection system brush.