BS-7/L: Low-voltage power cable
Power supply – FPGA Board
Power supply
CN2
CN7
Signal
Color
FPGA Board
CN3
1
-
+ 12 V
Red
1
3
-
+ 5 V
Orange
4
4 -
Ground
Gray
3
5 Faston
Earth
Black
2
The connection between connector CN7 and pin 5 on connector CN2, both on the power supply,
serves to ground the low voltage grounding socket (0 V).
BS-4: Low voltage cable
FPGA Board – CPU Board
FPGA board
CN4
Signal
Color
CPU Board
K1
1
+ 12 Vdc
Red
1
2 Ground
Black
2
3 Ground
Gray
3
4
+ 5 Vdc
Orange
4