![Technogym BIOSTRENGTH LINE Service Maintenance Manual Download Page 582](http://html1.mh-extra.com/html/technogym/biostrength-line/biostrength-line_service-maintenance-manual_1070169582.webp)
BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 8.8
8.2.3. L
EG
E
XTENSION
Figure 8.2.3-1
With the primary and secondary shaft chain and
weight stack cable disconnected:
1. With the limit switch at the end of its stroke
and the lever in position 1, adjust the position
of the PRIMARY SHAFT so that it respects
the measurements shown in the drawing.
2. To do so, adjust the position of the limit
switch by regulating the screw and nut with a
17-gauge wrench.
Figure 8.2.3-2
3. The cam and pinion of the secondary shaft
must be connected so that the punch
∅
2 on a
tooth of the pinion is aligned with the hole in
the cam.
Continued on next page
→