BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 2.22
BS-12: High-voltage power cable
Power switch – Fuses
Power switch
CN14
Signal
Color
Fuses
CN15
Faston Neutral
Black
Faston
Faston Phase
Black
Faston
BS-13: High-voltage power cable
Fuses – Filter – Earth node
Fuses
CN16
Signal
Color
CN17
Filter
PE
Faston Neutral
Black
Faston -
Faston Phase
Black
Faston -
- Earth
Yellow–
green
Faston Slot
BS-14/S: High-voltage power cable
Filter – Power supply – 110/230 Selector switch
Filter
CN18
Signal
Color
Power supply
CN1
Selector switch
CN1
Slot Ground
Yellow
1
-
4 -
Faston Neutral
Blue
- 2
6 -
Faston Phase
Black
- 1
BS-7/L: Low-voltage power cable
Power supply – Bio Driver Board
Power supply
CN2
CN7
Signal
Color
Bio driver
board
CN9
1
-
+ 12 V
Red
1
3
-
+ 5 V
Orange
4
4 -
Ground
Gray
3
5 Faston
Earth
Black
2
The connection between connector CN7 and pin 5 on connector CN2, both on the power supply,
serves to ground the low voltage grounding socket (0 V).
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......