6.13. THE LCD DISPLAYS THE MESSAGE “SEAT PROBLEM =
FAIL”
This error message appears when the CPU board receives an alarm signal from the Bio servo board
(LP Bio servo), in addition to the first considered to be normal, after enabling movement of the seat
motor in one direction. This signal means that the absorbed current of the motor is greater than a
value preset on the board by means of the setting described in paragraph 8.16., due to:
•
Low current limit setting;
•
Insufficient lubrication of the seat adjustment system;
•
Damaged motor.
Check these parts; when you find the defective one, replace it to restore machine operation.