BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.286
To disassemble the TRANSFORMER
f
:
1. Disconnect the secondary cables from the
board connectors.
2. Unsolder the primary cables from the selector
switch.
3. Unscrew the holding screw a using an 8-
gauge wrench.
4. Remove the transformer.
To disassemble the 110/220 SELECTOR
SWITCH
g
:
1. Unsolder the cables.
2. Unscrew the holding nut.
3. Remove the selector switch.
To disassemble the FILTER
h
:
1. Disconnect the connectors.
2. Unscrew the 2 holding nuts.
To reassemble the ELECTRONIC
COMPONENTS OF THE ELECTRICAL BOX,
follow the above steps in reverse order.