BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.391
7.9.41. D
ISASSEMBLING THE LEVERS
Figure 7.9.41-1
Follow the steps described in paragraphs 7.9.38.
“Disassembling the tachogenerator guard” and
7.9.39. “Disassembling the front guard”.
For each LEVER:
1. Use a 2-gauge hexagonal T-wrench to
unscrew the 6 screws
a,
holding the screw in
place from the opposite side with a 6-gauge
hexagonal T-wrench.
2. Remove the lever mat.
Figure 7.9.41-2
3. Unscrew the 4 screws
b
using a 17-gauge
wrench.
4. Remove the LEVER counter-weight.
Hold the LEVER counter-weight up
before unscrewing the last screw. Use
caution, as it weighs approximately 45
Kg.
For each side of the machine and each LEVER
arm:
5. Use a 30-gauge Allen wrench to unscrew the
ring-nut
c
, holding the screw
d
in place with
a 6-gauge hexagonal T-wrench.
6. Remove the shaft
e
.
7. Remove the LEVER arms.
To reassemble the LEVERS, follow the above
steps in reverse order
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......