BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.115
7.3.29. D
ISASSEMBLING THE WEIGHT STACK CABLE
Figure 7.3.29-1
Follow the steps described in paragraphs 7.3.7.
“Disassembling the Plexiglas weight stack
guard” for just one part and 7.3.28.
“Disassembling the weight stack frame guard”.
1. Using 2 22-gauge wrenches, loosen the
counter-nut
a
then unscrew the screw
b
from
the WEIGHT STACK CABLE terminal until
it is free from the cross.
Figure 7.3.29-2
2. Unscrew the 2 dowels
c
using a 4-gauge
hexagonal T-wrench.
3. Remove the cable with the aid of a pair of
pliers.
To reassemble the WEIGHT STACK CABLE,
follow the above steps in reverse order.
When the operation is complete, adjust
the tension of the WEIGHT STACK
CABLE, and the phasing of the cam and
lever mechanism, as described in
paragraphs 8.4. and 8.2. .