BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.73
7.2.29. D
ISASSEMBLING THE BELL
Figure 7.2.29-1
Follow the steps described in paragraphs 7.2.25.
“Disassembling the bell guard” and 7.2.28.
“Disassembling the release lever cable”.
1. Unscrew the screw
a
using a 6-gauge
hexagonal T-wrench.
2. Remove the BELL.
To reassemble the BELL, follow the above steps
in reverse order.
During reassembly, make sure that the
BELL pin is inserted in the hole
provided in the round part connected to
the primary shaft between the
movement limitation pins.