BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.40
6.16. THE LCD DISPLAYS THE MESSAGE “SEAT PROBLEM =
ENCODER”
This error message appears during the initial machine reset, when the CPU board does not receive
the encoder signal from the Bio servo board once it has detected a change in the alarm signal, after
enabling movement of the seat motor in one direction. This means that there is movement, but no
encoder signal.
6.16.1. F
OR
L
EG
P
RESS
SEAT PROBLEM =
ENCODER
Replace the photocell
Check whether the seat motor
encoder output signal from the
photocell is correct
NO
2
YES
Check whether the photocell
board is powered
1
YES
B
NO
A
YES
Check whether the seat motor
encoder output signal from the LP
driver board is correct
NO
4
Replace the LP driver
board
YES
Check whether the seat motor
encoder input signal to the LP
driver board is correct
3
NO
Replace the cables
between the motor and
the LP driver board
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......